HI 145
Rugged Thermometers with T-shaped Handle Designed for HACCP Control with ±0.3°C Accuracy and Cal-Check®
Description
HI 145 thermometers have been developed for HACCP programs and offer high standards of performance together with maximum simplicity-of-use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion, such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications. The HI 145 thermometer is ideally suited for monitoring incoming merchandise and food storage, as well as applications in food preparation, and during cooking.
HI 145-00 and HI 145-01 are equipped with a 5" (125mm) long AISI 316 stainless steel probe. The sharp conical tip provides fast response and improved accuracy over the entire range. HI 145-20 and HI 145-30 are supplied with a 12" (300mm) long stainless steel probe; ideal for monitoring hot liquids, such as deep frying and soup preparation.
Automatic Calibration Check
The HI 145 series is equipped with the exclusive Cal-Check feature. When the instrument is turned on, it performs a self check of its calibration status and displays it on the LCD. Accuracy is assured and your measurements are reliable.
Specifications
| Range | HI 145-00 | -50.0 to 220°C |
| Range | HI 145-01 | -58.0 to 428°F |
| Range | HI 145-20 | -50.0 to 220°C |
| Range | HI 145-30 | -58.0 to 428°F |
| Resolution | HI 145-00 | 0.1°C (-50.0 to 199.9°C) 1°C (200 to 220°C) |
| Resolution | HI 145-01 | 0.1°F (-58.0 to 199.9°F) 1°F (200 to 428°F) |
| Resolution | HI 145-20 | 0.1°C (-50.0 to 199.9°C) 1°C (200 to 220°C) |
| Resolution | HI 145-30 | 0.1°F (-58.0 to 199.9°F) 1°F (200 to 428°F) |
| Accuracy | HI 145-00 | ±0.3°C (-20.0 to 90.0°C); ±0.4% F.S. (outside) |
| Accuracy | HI 145-01 | ±0.6°F (-4 to 194.0°C); ±0.4% F.S. (outside) |
| Accuracy | HI 145-20 | ±0.3°C (-20.0 to 90.0°C); ±0.4% F.S. (outside) |
| Accuracy | HI 145-30 | ±0.6°F (-4 to 194.0°C); ±0.4% F.S. (outside) |
| Probe | HI 145-00 | stainless steel 125 x dia 5 mm (4.9 x dia 0.2") |
| Probe | HI 145-01 | stainless steel 125 x dia 5 mm (4.9 x dia 0.2") |
| Probe | HI 145-20 | stainless steel 300 x dia 5 mm (11.8 x dia 0.2") |
| Probe | HI 145-30 | stainless steel 300 x dia 5 mm (11.8 x dia 0.2") |
| Battery Type / Life | HI 145-00 | 1 x 1.5V AAA / approx. 10000 hours of continuous use; auto-off after 8 minutes of non-use |
| Battery Type / Life | HI 145-01 | 1 x 1.5V AAA / approx. 10000 hours of continuous use; auto-off after 8 minutes of non-use |
| Battery Type / Life | HI 145-20 | 1 x 1.5V AAA / approx. 10000 hours of continuous use; auto-off after 8 minutes of non-use |
| Battery Type / Life | HI 145-30 | 1 x 1.5V AAA / approx. 10000 hours of continuous use; auto-off after 8 minutes of non-use |
| Environment | HI 145-00 | -10 to 50°C (14 to 122°F); RH max 95% |
| Environment | HI 145-01 | -10 to 50°C (14 to 122°F); RH max 95% |
| Environment | HI 145-20 | -10 to 50°C (14 to 122°F); RH max 95% |
| Environment | HI 145-30 | -10 to 50°C (14 to 122°F); RH max 95% |
| Dimensions | HI 145-00 | 92 x 165 x 38 mm |
| Dimensions | HI 145-01 | 92 x 165 x 38 mm |
| Dimensions | HI 145-20 | 92 x 340 x 38 mm |
| Dimensions | HI 145-30 | 92 x 340 x 38 mm |
| Weight | HI 145-00 | 65 g (2.3 oz.) |
| Weight | HI 145-01 | 65 g (2.3 oz.) |
| Weight | HI 145-20 | 80 g (2.8 oz.) |
| Weight | HI 145-30 | 80 g (2.8 oz.) |